At Spares Universe,we provide safe, durable, and affordable NSN part fulfillment solutions for customers within a wide variety of industries. This includes our selection of dependable Transformer Power items like NSN 5950-00-472-3590. If you are interested in purchasing part number 10P14CT by Abbott Technologies Inc, we encourage you to begin by submitting the Request for Quote (RFQ) form below to receive a competitive quote in 15 minutes or less. Using the details you provide in your form, including shipping deadlines, desired quantities, and more, we will find a solution for sourcing part number 10P14CT that caters to your particular situation.
Note : We Will Not Share Your Information To Any Third Parties.
Part number 10P14CT is produced by Abbott Technologies Inc under the CAGE Code 58910, and this manufacturer is a trusted entity on our Approved Vendor List (AVL) who follows a strict level of quality assurance in their practices. They are also part of our vast supply network which allows for expedited shipping solutions for domestic and international customers alike. If you would like to explore other products with the NSN 5950-00-472-3590 or similar parts, we invite you to check out our page of 5950 Coils and Transformers products or look at the list of related items below.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-472-3590 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004723590 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10P14CT | 6 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.032 INCHES MINIMUM AND 2.032 INCHES MINIMUM AND 2.032 INCHES MINIMUM AND 2.032 INCHES MINIMUM AND 2.094 INCHES MAXIMUM2.094 INCHES MAXIMUM2.094 INCHES MAXIMUM2.094 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.484 INCHES MINIMUM SINGLE MO |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.234 INCHES MINIMUM SINGLE MO |
ABKW | OVERALL HEIGHT | 3.001 INCHES MINIMUM AND 3.001 INCHES MINIMUM AND 3.001 INCHES MINIMUM AND 3.001 INCHES MINIMUM AND 3.249 INCHES MAXIMUM3.249 INCHES MAXIMUM3.249 INCHES MAXIMUM3.249 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.719 INCHES MINIMUM AND 1.719 INCHES MINIMUM AND 1.719 INCHES MINIMUM AND 1.719 INCHES MINIMUM AND 1.781 INCHES MAXIMUM1.781 INCHES MAXIMUM1.781 INCHES MAXIMUM1.781 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT440.0 HERTZ MAXIMUM SINGLE COMPONENT440.0 HE |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 10.0 VOLT-AMPERE SINGLE COMPONENT10.0 VOLT-AMPERE SINGLE COMPONENT10.0 VOLT-AMPERE SINGLE COMPONENT10.0 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALEDHERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 640.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 14.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK |